• A tissue grinder for surface water chlorophyll a analysis
  • DHFSTPRP-Ch24
  • A tissue grinder for surface water chlorophyll a analysis
  • 24*(0.2-0.5ML) /24*2ML
developed specifically to meet the standard for chlorophyll a determination in water quality - "Spectrophotometric Method for Chlorophyll a Measurement in Water - HJ 897-2017" established by the Ministry of Ecology and Environment of China.
Application of Standard Method for Chlorophyll Extraction:
1. Filtration: add magnesium carbonate suspension before filtration to prevent pigment decomposition. The negative pressure should not exceed 50 kPa.
2. Chlorophyll extraction: place the filter membrane in a DHFSTPRP-Ch24 extractor, add 10 mL of 90% acetone solution, and grind at 1500-2000 rpm for 1 minute. The broken filter membrane floats the planktonic algae cells. After grinding, soak and extract at 4℃ in the dark for 15 minutes to 24 hours. Finally, centrifuge for clarification: centrifuge at 1000g for 20 minutes or filter, and transfer the supernatant to a stoppered glass vial.
3. Measurement method: spectrophotometry. Use the tricolor equation to determine the absorbance at 664 nm, 647 nm, 630 nm, and 750 nm to calculate the chlorophyll a, b, and c contents. Use the single-color equation to determine the content of demagnesiated chlorophyll a after calibration.
DHFSTPRP-Ch24 can simultaneously process 8×10mL centrifuge tubes, etc. for rapid cell disruption, cell lysis, and tissue homogenization.
Sample grinding includes plant roots, stems, leaves, flowers, fruits, seeds, and certain animal tissues; it is particularly suitable for the extraction of nucleic acids, proteins, and other components in plant tissues. In addition, it can also crush yeasts, cultured animal cells, bacterial cells, etc. to extract their components.
The three-dimensional integrated shaking mode makes the sample grinding more uniform and sufficient, with good repeatability of samples and no cross-contamination between samples. It is a true high-throughput grinding and oscillation system. Each sample can be completed in only 1-2 minutes.
The Eupervs accessory can be selected for low-temperature grinding and preservation of temperature-sensitive samples.


Applicable Samples and Applications:
1. Fast grinding preparation for PCR (polymerase chain reaction) of multiple samples.
2. Rapid tissue homogenization for nucleic acid extraction, RNA/DNA extraction, and protein extraction.
3. Lysis of yeast and bacterial cells.
4. Pesticide/Insecticide analysis (sample processing for residual pesticides or toxic substances in food using LC/MS/MS).
5. QuEChERS method (extraction of pesticides, antibiotics, and drugs).
6. Extraction of active pharmaceutical ingredients (APIs).
7. Food safety (contamination, adulteration, food traceability).
8. Grinding and homogenization of biomass for biofuels.


Experimental Steps:
homogenizer_tissuelyser


Main Features:
• A specially designed grinder for extracting nucleic acids and protein components from plant samples.
• High throughput: can simultaneously grind 8*10ml samples and is suitable for grinding samples of various sizes, greatly improving work efficiency.
• Each sample can be completed in only 1-2 minutes.
• In order to ensure the reproducibility, effectiveness, and comparability of the samples, the grinder can set the grinding time, grinding rate, and cycle times, to ensure the consistency between each grinding and the next, with a maximum time of 99 minutes.
• Built-in with two safety locks and one sample chamber cover interlock, extremely safe and reliable.
• Customized solutions for grinding samples of animals and plants at room temperature or low temperature.
• The start and stop buttons allow the user to start or stop the grinding process at any time.
• Optional uways low-temperature accessories for low-temperature grinding and storage of temperature-sensitive RNA and protein extraction samples.


Technical Specifications  
Application areas: Organ homogenization, grinding, cell disruption, homogenization, material dispersion, preparation, sample mixing, and oscillation
Processing capacity: 24 samples can be processed simultaneously within 15 seconds, and it can be used with 12- and 24-position liquid nitrogen cryogenic adapters
Compatible sample tubes: 24*(0.2-0.5ML) /24*2ML /8*(5-15)ML /4*25ML /2*50ML, and various specifications of grinding tubes can be customized
Display mode: Touchscreen display (for convenient and intuitive operation)
Ten sets of experimental data can be stored: According to different experimental samples, animal heart, spleen, lung, kidney, bone, skin, and hair patterns are set up
Cycle mode: According to the set experimental parameters, it can continuously cycle among several preset parameters, further reducing human interference
Anti-vibration principle: Innovative anti-vibration principle DHFSTPRP-1, and a special three-dimensional vibration mode of up and down and left and right shaking, the sample moves in 8-shaped three-dimensional space, with innovative grinding ball motion mode to ensure ideal sample processing and instant crushing effect
Maximum feeding size: No requirement, adjustable according to the adapter
Final output particle size: ~5μm
Number of grinding platforms: (Accepts more than 2 grinding jars)
Fastening device: With automatic centering and positioning
Homogenization speed: 0~70 Hz/second, working time: 0 seconds to 99 minutes, user can set it themselves
Grinding ball diameter: 0.01~30mm
Grinding ball material: Alloy steel, chrome steel, zirconia oxide, tungsten carbide, and quartz sand
Acceleration: Reaching high speed within 2 seconds
Deceleration: Reaching low speed within 2 seconds
Noise level: <55db
Grinding method: Wet grinding, dry grinding, and low-temperature grinding are all possible
Temperature control can be equipped: With the ability to upgrade to ultra-low temperature liquid nitrogen cooling or air cooling
Adapter material: Polytetrafluoroethylene, alloy steel
Safety instructions: With an automatic centering and locking device for safe operation throughout
Grinding kit materials: Hard alloy, polytetrafluoroethylene (PTFE), zirconia
Dimensions: 630*300*480mm
Weight: 60 Kg


Results of Surface Water Chlorophyll Tissue Grinder Experiment:

homogenizer_tissuelyser
 

homogenizer_tissuelyser
 


Single Page - Color Page    
Name: Author: Action:
A tissue grinder for surface water chlorophyll a analysis DHFSTPRP-Ch24 homogenizer Download


Related products  
Name: Model:
A tissue grinder for surface water chlorophyll a analysis DHFSTPRP-Ch24
Product List
DHFSTPRP-Ch24 Unit
Host Machine Unit
Adapters set
Cooling Adapter Set
Zirconia Grinding Bead No.5 Piece
Zirconia Grinding Bead No.3 Piece
Special Grinding Tube Piece
Special Bead Loading Gun Set
Description
1
?10ml,1(2 in 1)
?10or?15ml,1(2 in 1)
1000(2 in 1)
1000(2 in 1)
200
1(Optional)
主站蜘蛛池模板: 亚洲 自拍 另类小说综合图区| 91精品国产综合久久四虎久久无码一级| 久久综合九色欧美综合狠狠| 亚洲伊人tv综合网色| 天天影视色香欲综合久久| 久久久久综合网久久| 91超碰碰碰碰久久久久久综合 | 久久本道久久综合伊人| 婷婷久久综合九色综合九七| 亚洲色图综合网| 久久亚洲欧洲国产综合| 亚洲综合图色40p| 久久久久久久综合日本亚洲| 国产欧美日韩综合精品一区二区三区| 日韩欧美色综合网站| 色综合久久综精品| 亚洲综合AV在线在线播放| 亚洲综合一区二区精品导航| 久久综合伊人77777麻豆| 色综合中文字幕| 亚洲欧美综合另类图片小说区| 狠狠色丁香久久综合五月| 天堂久久天堂AV色综合| 久久综合偷偷噜噜噜色| 婷婷久久综合九色综合绿巨人 | 色综合婷婷在线观看66| 色狠狠色狠狠综合一区| 欧美激情中文字幕综合一区| 久久综合九色综合97_久久久| 伊人成年综合网| 人人狠狠综合久久亚洲高清| 色婷婷综合缴情综免费观看| 伊人久久大香线焦AV综合影院| 狠狠色丁香婷婷综合久久来 | 狠狠色丁香婷婷久久综合| 综合在线免费视频| 国产精品激情综合久久| 亚洲综合欧美精品一区二区| 狠狠色综合色综合网络| 亚洲 欧美 国产 动漫 综合| 五月天激情综合|